OCPP error code in StatusNotification;DTC;Description
ConnectorLockFailure;0x100205;Gun lock control failure
EVCommunicationError;0x100204;BMS communication timeout
GroundFailure;0x100206;Ground Fault
HighTemperature;0x100101;Overtemperature fault inside the terminal
InternalError;0x200101;Module DC is over temperature
InternalError;0x200001;Power module communication failure
InternalError;0x200002;Power module alarm and failure
InternalError;0x100202;Terminal emergency stop failure
InternalError;0x100201;End of product trial period
InternalError;0x100208;Output relay control failure
InternalError;0x100209;Discharge resistance failure
InternalError;0x100207;Insulation monitoring board failure (communication, hardware)
InternalError;0x100203;Auxiliary power control failure
InternalError;0x300101;Liquid cooling equipment failure (mechanical, over-temperature)
InternalError;0x200003;PDU relay control failure
InternalError;0x200004;PDU communication failure
InternalError;0x200009;Front-end AC meter failure (communication, data abnormality)
InternalError;0x200102;PDU over temperature fault
InternalError;0x200201;Abnormal power control output
InternalError;0x100212;Abnormal communication with the rectifier cabinet
InternalError;0x200103;Abnormal power control fan communication
InternalError;0x200104;Power control fan failure (alarm)
InternalError;0x200202;Power cabinet emergency stop failure
InternalError;0x100001;Terminal touch screen touch failure
InternalError;0x100002;Terminal touch screen light sensor failure
InternalError;0x100009;The external storage of the terminal is abnormal
InternalError;0x200005;Power cabinet touch screen touch failure
InternalError;0x200006;Power cabinet touch screen light sensor failure
InternalError;0x200007;Abnormal external storage of power cabinet
InternalError;0x100210;Communication failure with the backplane
InternalError;0x100003;Sensor communication failure
InternalError;0x200105;Power cabinet over temperature alarm
InternalError;0x100004;Software update failed
InternalError;0x100211;Power failure
InternalError;0x100102;Cable connector over temperature alarm
InternalError;0x100103;Cable joint temperature difference alarm
InternalError;0x300102;Liquid cooling equipment leak
InternalError;0x400101;Chiller system failure
InternalError;0x100214;Output overvoltage fault
InternalError;0x100215;RCD warm/fault
InternalError;0x100216;PLC board offline
NoError;;
OtherError;0x10020A;BMS insulation fault
OtherError;0x10020B;Terminal level alarm
OtherError;0x200203;Power cabinet liquid level alarm
OtherError;0x10020C;Terminal door open
OtherError;0x200204;Power cabinet door open
OtherError;0x200205;Output short circuit
OtherError;0x100104;High pressure warning
OtherError;0x10020D;High humidity alarm
OtherError;0x200008;Input surge protection alarm
OtherError;0x10020E;Pile tilt warning
OverCurrentFailure;0x100213;Overcurrent fault
OverVoltage;0x200206;Input overvoltage fault
PowerMeterFailure;0x10020F;Meter failure (communication, data error)
PowerSwitchFailure;0x200207;Input relay control failure
ReaderFailure;0x100005;Card reader communication failure
ResetFailure;0x100006;Reset failed (hardware, software)
UnderVoltage;0x200208;Input undervoltage fault
WeakSignal;0x100008;Weak wireless signal
OtherError;0x100217;CP detection failure
OtherError;0x100218;The gun lines don't match
OtherError;0x100007;Communication failure with lamp board
OtherError;0x100008;The communication with the screen is faulty
EVCommunicationError;0x100219;Automobile communication failure
;0x10021A;The communication with the mainboard is faulty
;0x10021B;Time out to get tip information
;0x10021C;Breaker off
;0x10021D;PLC reply of pile tip information timed out
;0x10021E;Discharge timeout
;0x10021F;Prefi lled timeout
;0x100220;Gun connection disconnected